Home | << 1 >> |
Carmalt, J. L., Carmalt, K. P., & Barber, S. M. (2006). The effect of occlusal equilibration on sport horse performance. J Vet Dent, 23(4), 226–230.
Abstract: The objective of this study was to investigate the effect of routine dental occlusal equilibration treatment on dressage horse performance. Sixteen horses (11 treated; 5 untreated) ridden by a single rider performed a standardized dressage test twice and were scored by two experienced dressage judges according to recognized movements and rider cues. All horses were sedated and a full-mouth speculum was used to facilitate a complete oral examination. Treated horses had dental equilibration performed using a motorized dental instrument. The horses performed a second test 48-hours after dental equilibration, exactly as the baseline test, with the judges and rider blinded as to treatment group. The total test score as well as the individual movement scores were evaluated for equality of variance and statistical tests were applied to determine the influence of treatment. There was no significant improvement in the test score of horses that had received occlusal equilibration.
|
Hedberg, Y., Dalin, A. - M., Ohagen, P., Holm, K. R., & Kindahl, H. (2005). Effect of oestrous-cycle stage on the response of mares in a novel object test and isolation test. Reprod Domest Anim, 40(5), 480–488.
Abstract: In various species, sex, hormonal treatments and oestrous-cycle stage have been shown to affect the animal's response in behavioural tests. Few such studies have been performed in the horse. The main aim of the present study was to investigate whether oestrous-cycle stage affects mares' response to a novel object test and isolation test and, in part, to study whether mares, assumed to suffer from oestrous-related behavioural problems, respond differently in these tests when compared with controls. Twelve mares were tested twice, in oestrus and dioestrus, in a crossover design. Seven behavioural and two heart rate variables were measured for the novel object test and two heart rate variables for the isolation test. Oestrous-cycle stage and whether a mare was classified as a 'problem' mare did not affect the mare's response. However, test order, i.e. the cycle stage a mare was tested in first, affected its reaction. This effect could partly be explained by significant differences between test occasions 1 and 2 in three behavioural variables and one heart rate variable (p < 0.05) in the novel object test. The mares explored the novel object more and had a higher mean heart rate in the first test. Exploring the novel object more could largely be attributed to those mares tested in dioestrus first, perhaps indicating that the mares in oestrus were less receptive to the novel object. The reason for the differences between test occasions could be an effect of learning or habituation.
|
Natalini, C. C., & Robinson, E. P. (2003). Effects of epidural opioid analgesics on heart rate, arterial blood pressure, respiratory rate, body temperature, and behavior in horses. Vet Ther, 4(4), 364–375.
Abstract: Heart rate, arterial blood pressures, respiratory rate, body temperature, and central nervous system excitement were compared before and after epidural administration of morphine (0.1 mg/kg), butorphanol (0.08 mg/kg), alfentanil (0.02 mg/kg), tramadol (1.0 mg/kg), the k-opioid agonist U50488H (0.08 mg/kg), or sterile water using an incomplete Latin square crossover design in five conscious adult horses. Treatments were administered into the first intercoccygeal epidural space. Significant (P <.05) reductions in respiratory rate were detected after epidural administration of morphine, alfentanil, U50488H, and sterile water. Additionally, significant (P <.05) head ptosis was observed within the first hour after administration of morphine, U50488H, and tramadol, but neither of these changes appeared to be of clinical significance. No treatment-related changes in motor activity or behavior were observed.
Keywords: 3,4-Dichloro-N-methyl-N-(2-(1-pyrrolidinyl)-cyclohexyl)-benzeneacetamide, (trans)-Isomer/administration & dosage/pharmacology; Alfentanil/administration & dosage/pharmacology; Analgesics, Opioid/administration & dosage/*pharmacology; Anesthesia, Epidural/*veterinary; Animals; Behavior, Animal/drug effects; Blood Pressure/drug effects; Body Temperature/drug effects; Butorphanol/administration & dosage/pharmacology; Cross-Over Studies; Female; Heart Rate/drug effects; Horses/*physiology; Injections, Epidural/veterinary; Male; Morphine/administration & dosage/pharmacology; Respiration/drug effects; Tramadol/administration & dosage/pharmacology
|
Rapin, V., Poncet, P. A., Burger, D., Mermod, C., & Richard, M. A. (2007). [Measurement of the attention time in the horse]. Schweiz Arch Tierheilkd, 149(2), 77–83.
Abstract: A study carried out on 49 horses showed that it is possible to measure the attention time by operant conditioning. After teaching horses an instrumental task using a signal, we were then able to test their attention time by asking them to prolong it increasingly while setting success and failure criteria. Two tests were performed 3 weeks apart. The 2nd test was feasible without relearning, a proof of memory, and was repeatable, a proof of consistency in the attention time. A significant difference was observed between the 3 age groups. Young horses often performed very well during the 1st test but their attention dropped in the 2nd test while older horses were more stable with respect to attention and even increased it slightly. The study shows that there are individual differences but it was not possible to prove a significant influence of breed, gender and paternal influence. Consequently, learning appears to be one of the most interesting approaches for evaluating the attention of horses and for observing their behaviour.
|
Sloet van Oldruitenborgh-Oosterbaan, M. M., Spierenburg, A. J., & van den Broek, E. T. W. (2006). The workload of riding-school horses during jumping.
Abstract: REASONS FOR PERFORMING THE STUDY: As there are no reports on the real workload of horses that jump fences, this study was undertaken in riding-school horses. OBJECTIVE: To compare the workload of horses jumping a course of fences with that of horses cantering over the same course at the same average speed without jumping fences. The workload variables included heart rate (HR), packed cell volume (PCV), acid-base balance (venous pH, pCO2, HCO3-) and blood lactate (LA), glucose, total protein and electrolyte concentrations. METHODS: Eight healthy riding-school horses performed test A (a course of approximately 700 m with 12 jumps from 0.8-1.0 m high at an average speed of approximately 350 m/min) and test B (same course at the same speed, but without the rails) in a crossover study with at least 4 h between the 2 tests. Before each test the horses were fitted with a heart rate meter (Polar Electro). Blood samples were taken from the jugular vein at rest prior to the test, after warm-up before starting the course, immediately after the course and after recovery. All samples were analysed immediately. RESULTS: The mean +/- s.d maximal HR (beats/min) during the course (184 +/- 17 and 156 +/- 21, respectively) and the mean HR after recovery (75 +/- 6 and 63 +/- 7, respectively) were significantly higher in test A compared to test B (P = 0.001 and P = 0.007 respectively). The mean LA concentrations after the course and after recovery (mmol/l) were significantly higher in test A (3.6 +/- 2.7 and 1.0 +/- 0.9, respectively) compared to test B (0.9 +/- 0.5 and 0.3 +/- 0.1, respectively), (P = 0.016 and P = 0.048 respectively). The mean PCV (I/l) after the course and after recovery was also significantly different between tests A (0.48 +/- 0.04 and 0.39 +/- 0.03, respectively) and B (0.42 +/- 0.04 and 0.36 +/- 0.03, respectively) (P<0.01). The mean pH and the mean HCO3- (mmol/l) after the course were significantly lower in test A (7.40 +/- 0.04 and 28.9 +/- 1.4, respectively) compared to test B (7.45 +/- 0.03 and 30.4 +/- 2.3, respectively) (P<0.05). CONCLUSIONS: This study indicates that in riding-school horses jumping fences, even at a low level competition, provokes a significant workload compared to cantering the same distance and speed without fences. POTENTIAL RELEVANCE: This study makes it clear that the extra workload of jumping fences should be taken into account in the training programmes of jumping horses. Further research with more experienced horses jumping higher fences will reveal the workload for top-level jumping horses.
Keywords: Acid-Base Equilibrium/physiology; Animals; Blood Gas Analysis/veterinary; Blood Glucose/metabolism; Cross-Over Studies; Electrolytes/blood; Female; Heart Rate/*physiology; Hematocrit/veterinary; Horses/blood/*physiology; Lactates/*blood; Male; Physical Conditioning, Animal/*physiology; *Sports; Time Factors; Water-Electrolyte Balance/physiology
|