Details
   web
Records
Author (up) Hebenbrock, M.; Due, M.; Holzhausen, H.; Sass, A.; Stadler, P.; Ellendorff, F.
Title A new tool to monitor training and performance of sport horses using global positioning system (GPS) with integrated GSM capabilities Type Journal Article
Year 2005 Publication DTW. Deutsche Tierarztliche Wochenschrift Abbreviated Journal Dtsch Tierarztl Wochenschr
Volume 112 Issue 7 Pages 262-265
Keywords Animals; Heart Rate; Horses/*physiology; *Physical Conditioning, Animal; Population Surveillance; *Satellite Communications; Telemetry/methods/*veterinary
Abstract Global Positioning Systems (GPS) are considered suitable to monitor the position and velocity of horses during cross-country competition or in training. Furthermore, simultaneous recording of life data such as heart rate could be useful to assess the horse's condition during exercise. To test the suitability and reliability of a commercially available GPS system with integrated heart rate recording system and with built in GSM for data transmission, the Fidelak Equipilot Type EP-2003-15/G-2.11 (EP-15/G) was evaluated first for reliability of pulse recording from a pulse generator within the physiological range of horses; furthermore distance, velocity and heart rate recordings were carried out on a standard 1000 m field track with five repetitions. Agreement (% deviation from actually measured distance and from stopwatch-distance based velocity calculations) and variability (Coefficient of Variation for distance, velocity, heart rate) were calculated. From the results it was safe to assume that the heart rate sensor recorded horse heart rates at a high degree of accuracy. Overall distances and velocities are in high agreement with actually measured values. However, overall variability expressed in terms of relative variability (C.V.) is smaller for distance recording (C.V. 0.68%) when compared to velocity (C.V. 1.01%). The system tested is suitable and reliable for simultaneously recording of distance, velocity and heart rates for horses during cross country exercise. GPS-based monitoring of movement along with simultaneous recording of physiological data and the possibility to call upon data will not only be of benefit for training horses or for surveillance during competition, it may also be suitable for distant patient monitoring and in behavioural studies as well as in veterinary medicine in general.
Address Institute for Animal Breeding Mariensee, Federal Agricultural Research Centre (FAL), Neustadt, Germany
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0341-6593 ISBN Medium
Area Expedition Conference
Notes PMID:16124700 Approved no
Call Number Equine Behaviour @ team @ Serial 4035
Permanent link to this record
 

 
Author (up) Stadler, P.; Rewel, A.; Deegen, E.
Title [M-mode echocardiography in dressage horses, class S jumping horses and untrained horses] Type Journal Article
Year 1993 Publication Zentralblatt fur Veterinarmedizin. Reihe A Abbreviated Journal Zentralbl Veterinarmed A
Volume 40 Issue 4 Pages 292-306
Keywords Animals; Echocardiography/*veterinary; Female; Heart Septum/ultrasonography; Heart Ventricles/ultrasonography; Horses/*anatomy & histology; Male; *Physical Conditioning, Animal; Reference Values
Abstract Heart structures of 45 warmblooded horses were measured by M-mode-echocardiography. The current training level of 15 dressage horses (group I) and 15 show-jumping horses (group II) was category “S”. In the third group were 15 untrained horses. Four standardized transducer positions were determined for the m-mode echobeam, calibrated according to the two-dimensional real time technique. End systolic and end diastolic diameters of left ventricle, right ventricle, aortic root, interventricular septum and left ventricular wall, as well as motion pattern of heart wall, mitral valve and aortic valve of all horses were measured. The dressage horses showed a significant thickening of interventricular septum and left-ventricular wall compared with the show-jumping horses and the untrained horses. The end diastolic left ventricle diameter of the show-jumping horses was significantly larger than in the other groups. Compared to the untrained horses the show-jumping horses showed a significantly larger end systolic left ventricular wall diameter measured at the level of papillary muscle. It can be concluded, that an increase in heart mass in category “S” sport horses is attributed to their level of training.
Address Klinik fur Pferde der Tierarztlichen Hochschule Hannover
Corporate Author Thesis
Publisher Place of Publication Editor
Language German Summary Language Original Title Die M-mode-Echokardiographie bei S-Dressur-, S-Springpferden und bei untrainierten Pferden
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0514-7158 ISBN Medium
Area Expedition Conference
Notes PMID:8342361 Approved no
Call Number Equine Behaviour @ team @ Serial 3749