|   | 
Details
   web
Records
Author Youket, R.J.; Carnevale, J.M.; Houpt, K.A.; Houpt, T.R.
Title Humoral, hormonal and behavioral correlates of feeding in ponies: the effects of meal frequency Type Journal Article
Year 1985 Publication Journal of animal science Abbreviated Journal J. Anim Sci.
Volume (up) 61 Issue 5 Pages 1103-1110
Keywords Animals; Behavior, Animal/physiology; Blood Glucose/*analysis; Blood Proteins/*analysis; Blood Volume; *Eating; Feeding Behavior/physiology; Female; Heart Rate; Horses/blood/*physiology; Male; Osmolar Concentration; Osmotic Pressure; Triiodothyronine/*blood
Abstract The effect of meal frequency on body fluid, glucose, triiodothyronine (T3), heart rate and behavior was measured in 10 ponies. A simple reversal design was used in which each pony received one meal/day (1X) for 2 wk and six meals/day (6X) for 2 wk. The total intake/day was held constant. Feeding was followed by a rise in plasma levels of glucose, T3, protein and osmolality. One large meal was followed by significantly greater changes in all of the variables than was a meal one-sixth the size. Plasma T3 rose from 41 +/- 5 (SE) ng/liter before feeding to 43 +/- 5 ng/liter following a small meal, but rose significantly higher, from 39 +/- 4 to 60 +/- 10 ng/liter, following a large meal. Glucose rose from 84 +/- 3 to 109 +/- 7 mg/dl following a small meal and rose significantly higher, from 83 +/- 3 to 154 +/- 11 mg/dl, after a large meal. Plasma protein rose from 6.55 +/- .14 to 6.62 +/- .16 g/dl following a small meal and from 6.45 +/- .14 to 6.99 +/- .11 g/dl following a large meal. Osmolality rose from 227 +/- 1 mosmol/liter before to 279 +/- 1 mosmol/liter following a small meal and significantly higher from 278 +/- 2 to 285 +/- 1 mosnol/liter following a large meal. Heart rate rose from 42 beats/min in the absence of feed to 50 beats/min when food was visible to the ponies and did not rise higher when eating began. There were no significant differences in the cardiac response to one large meal and that to a small meal.(ABSTRACT TRUNCATED AT 250 WORDS)
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0021-8812 ISBN Medium
Area Expedition Conference
Notes PMID:4077755 Approved no
Call Number refbase @ user @ Serial 51
Permanent link to this record
 

 
Author Rosa, P.A.J.; Azevedo, A.M.; Aires-Barros, M.R.
Title Application of central composite design to the optimisation of aqueous two-phase extraction of human antibodies Type Journal Article
Year 2007 Publication Journal of Chromatography. A Abbreviated Journal J Chromatogr A
Volume (up) 1141 Issue 1 Pages 50-60
Keywords Analysis of Variance; Animals; Antibodies/*chemistry/*isolation & purification; Buffers; Chemical Fractionation/*methods; Horses; Humans; Hydrophobicity; Isoelectric Point; Models, Biological; Molecular Weight; Myoglobin/chemistry/isolation & purification; Osmolar Concentration; Phase Transition; Polyethylene Glycols; Serum Albumin/chemistry/isolation & purification; Sodium Chloride
Abstract The partition of human antibodies in aqueous two-phase systems (ATPSs) of polyethylene glycol (PEG) and phosphate was systematically studied using first pure proteins systems and then an artificial mixture of proteins containing 1mg/ml human immunoglobulin G (IgG), 10mg/ml serum albumin and 2mg/ml myoglobin. Preliminary results obtained using pure proteins systems indicated that the PEG molecular weight and concentration, the pH value and the salts concentration had a pronounced effect on the partitioning behaviour of all proteins. For high ionic strengths and pH values higher than the isoelectric point (pI) of the contaminant proteins, IgG could be selectively recovered on the top phase. According to these results, a face centred composite design was performed in order to optimise the purification of IgG from the mixture of proteins. The optimal conditions for the isolation of IgG were observed for high concentrations of NaCl and low concentrations of both phase forming components. The best purification was achieved using an ATPS containing 8% (w/w) PEG 3350, 10% (w/w) phosphate pH 6 and 15% (w/w) NaCl. A recovery yield of 101+/-7%, a purity of 99+/-0% and a yield of native IgG of 97+/-4% were obtained. Back extraction studies of IgG to a new phosphate phase were performed and higher yields were obtained using 10% phosphate buffer at pH 6. The total extraction yield was 76% and the purity 100%.
Address IBB Institute for Biotechnology and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Tecnico, Av Rovisco Pais, 1049-001 Lisbon, Portugal
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0021-9673 ISBN Medium
Area Expedition Conference
Notes PMID:17196214 Approved no
Call Number Serial 1842
Permanent link to this record