|
Records |
Links |
|
Author |
Hebenbrock, M.; Due, M.; Holzhausen, H.; Sass, A.; Stadler, P.; Ellendorff, F. |
|
|
Title |
A new tool to monitor training and performance of sport horses using global positioning system (GPS) with integrated GSM capabilities |
Type |
Journal Article |
|
Year |
2005 |
Publication |
DTW. Deutsche Tierarztliche Wochenschrift |
Abbreviated Journal |
Dtsch Tierarztl Wochenschr |
|
|
Volume |
112 |
Issue |
7 |
Pages |
262-265 |
|
|
Keywords |
Animals; Heart Rate; Horses/*physiology; *Physical Conditioning, Animal; Population Surveillance; *Satellite Communications; Telemetry/methods/*veterinary |
|
|
Abstract |
Global Positioning Systems (GPS) are considered suitable to monitor the position and velocity of horses during cross-country competition or in training. Furthermore, simultaneous recording of life data such as heart rate could be useful to assess the horse's condition during exercise. To test the suitability and reliability of a commercially available GPS system with integrated heart rate recording system and with built in GSM for data transmission, the Fidelak Equipilot Type EP-2003-15/G-2.11 (EP-15/G) was evaluated first for reliability of pulse recording from a pulse generator within the physiological range of horses; furthermore distance, velocity and heart rate recordings were carried out on a standard 1000 m field track with five repetitions. Agreement (% deviation from actually measured distance and from stopwatch-distance based velocity calculations) and variability (Coefficient of Variation for distance, velocity, heart rate) were calculated. From the results it was safe to assume that the heart rate sensor recorded horse heart rates at a high degree of accuracy. Overall distances and velocities are in high agreement with actually measured values. However, overall variability expressed in terms of relative variability (C.V.) is smaller for distance recording (C.V. 0.68%) when compared to velocity (C.V. 1.01%). The system tested is suitable and reliable for simultaneously recording of distance, velocity and heart rates for horses during cross country exercise. GPS-based monitoring of movement along with simultaneous recording of physiological data and the possibility to call upon data will not only be of benefit for training horses or for surveillance during competition, it may also be suitable for distant patient monitoring and in behavioural studies as well as in veterinary medicine in general. |
|
|
Address |
Institute for Animal Breeding Mariensee, Federal Agricultural Research Centre (FAL), Neustadt, Germany |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0341-6593 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:16124700 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
4035 |
|
Permanent link to this record |
|
|
|
|
Author |
Voss, B.; Mohr, E.; Krzywanek, H. |
|
|
Title |
Effects of aqua-treadmill exercise on selected blood parameters and on heart-rate variability of horses |
Type |
Journal Article |
|
Year |
2002 |
Publication |
Journal of Veterinary Medicine. A, Physiology, Pathology, Clinical Medicine |
Abbreviated Journal |
J Vet Med A Physiol Pathol Clin Med |
|
|
Volume |
49 |
Issue |
3 |
Pages |
137-143 |
|
|
Keywords |
Animals; Electrocardiography/veterinary; Exercise Test/veterinary; Female; Heart Rate/*physiology; Hemoglobins/metabolism; Horses/*physiology; Lactic Acid/blood; Male; Physical Conditioning, Animal/*physiology; Water |
|
|
Abstract |
The objectives of the present study were to investigate the effects of Aquatraining of horses (aqua-treadmill exercise; treadmill manufactured by Equitech – L.u.S. Equipment, Warendorf, Germany) on selected blood parameters [lactic acid concentration (mmol/l), haemoglobin content (g/l)] and on heart-rate variability (HRV) [heart rate (beats per min; b.p.m.), standard deviation of all NN-intervals (SDNN; ms), normalized power of the low and high frequency band (LFnorm, Hfnorm; au), % recurrence, % determinism and ratio(corr)]. Seven horses performed six exercise tests with different work loads (walking (x = 1.56 +/- 0.08 m/s) and trotting (x = 2.9 +/- 0.13 m/s): dry, water above the carpus and water above the elbow). The standardized test-protocol was: 5 min warm-up at walk while the water was pumped in, followed by the 20-min exercise period at walk or trot, followed by a 5-min walk while pumping out the water. Blood samples were taken prior to each test at rest in the stable, as well as exactly 5 min after the end of the 20-min exercise period. Electrocardiograms were recorded during rest and the 20-min exercise period. Compared to rest, neither the chosen velocities, the two water levels, nor the dry tests led to a significant increase of the lactic acid concentration in any horse. The haemoglobin content showed a significant increase as a result of exercise. Significant differences could be found between the heart rates at rest and the six exercise tests and between the mean of the levels 'walking' and the mean of the levels 'trotting'. An exercise-induced change of HRV was characterized by a decreasing SDNN, a significantly higher LFnorm (sympathetic influence) combined with a significantly lower HF(norm) power (parasympathetic activity) and a rising degree of order (significantly higher % determinism and nearly unchanged % recurrence) and stability (significantly rising ratio(corr)) of the recurrence plot. In conclusion, the used training-protocol for aqua-treadmill exercises only represents a medium-sized aerobic work load for horses, but the different levels of burden were indicated especially by changes in HRV. |
|
|
Address |
Institute for Veterinary Physiology of the Free University Berlin, Germany |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0931-184X |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:12019954 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
4049 |
|
Permanent link to this record |
|
|
|
|
Author |
Cattell, R.B.; Korth, B. |
|
|
Title |
The isolation of temperament dimensions in dogs |
Type |
Journal Article |
|
Year |
1973 |
Publication |
Behavioral Biology |
Abbreviated Journal |
Behav Biol |
|
|
Volume |
9 |
Issue |
1 |
Pages |
15-30 |
|
|
Keywords |
Aggression; Animals; *Behavior, Animal; Biometry; Body Weight; *Dogs; Emotions; Factor Analysis, Statistical; Female; Genetics, Behavioral; Heart Rate; Humans; Intelligence; Male; Models, Psychological; *Personality; Problem Solving; Social Behavior |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0091-6773 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:4738708 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
4140 |
|
Permanent link to this record |