|
Records |
Links |
|
Author |
Lin, Y.-L.; Moolenaar, H.; van Weeren, P.R.; van de Lest, C.H.A. |
|
|
Title |
Effect of microcurrent electrical tissue stimulation on equine tenocytes in culture |
Type |
Journal Article |
|
Year |
2006 |
Publication |
American Journal of Veterinary Research |
Abbreviated Journal |
Am J Vet Res |
|
|
Volume |
67 |
Issue |
2 |
Pages |
271-276 |
|
|
Keywords |
Animals; Apoptosis; Cell Proliferation; Cells, Cultured; Electric Stimulation; *Horses; Tendons/*cytology |
|
|
Abstract |
OBJECTIVE: To determine effects of microcurrent electrical tissue stimulation (METS) on equine tenocytes cultured from the superficial digital flexor tendon (SDFT). SAMPLE POPULATION: SDFTs were collected from 20 horses at slaughter. PROCEDURE: Tenocytes were isolated following outgrowth from explants and grown in 48-well plates. Four methods of delivering current to the tenocytes with a METS device were tested. Once the optimal method was selected, current consisting of 0 (negative control), 0.05, 0.1, 0.5, 1.0, or 1.5 mA was applied to cells (8 wells/current intensity) once daily for 8 minutes. Cells were treated for 1, 2, or 3 days. Cell proliferation, DNA content, protein content, and apoptosis rate were determined. RESULTS: Application of microcurrent of moderate intensity increased cell proliferation and DNA content, with greater increases with multiple versus single application. Application of microcurrent of moderate intensity once or twice increased protein content, but application 3 times decreased protein content. Application of current a single time did not significantly alter apoptosis rate; however, application twice or 3 times resulted in significant increases in apoptosis rate, and there were significant linear (second order) correlations between current intensity and apoptosis rate when current was applied twice or 3 times. CONCLUSIONS AND CLINICAL RELEVANCE: Results of the present study indicate that microcurrent affects the behavior of equine tenocytes in culture, but that effects may be negative or positive depending on current intensity and number of applications. Therefore, results are far from conclusive with respect to the suitability of using METS to promote tendon healing in horses. |
|
|
Address |
Department of Equine Sciences, Faculty of Veterinary Medicine, State University of Utrecht, Utrecht, The Netherlands |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0002-9645 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:16454632 |
Approved |
no |
|
|
Call Number |
|
Serial |
1878 |
|
Permanent link to this record |
|
|
|
|
Author |
de Cocq, P.; van Weeren, P.R.; Back, W. |
|
|
Title |
Saddle pressure measuring: Validity, reliability and power to discriminate between different saddle-fits |
Type |
Journal Article |
|
Year |
2006 |
Publication |
The Veterinary Journal |
Abbreviated Journal |
|
|
|
Volume |
172 |
Issue |
2 |
Pages |
265-273 |
|
|
Keywords |
Horse; Pressure; Back; Saddle; Saddle-fit |
|
|
Abstract |
Saddle-fit is recognised as an important factor in the pathogenesis of back problems in horses and is empirically being evaluated by pressure measurements in clinical practice, although not much is known about the validity, reliability and usability of these devices in the equine field. This study was conducted to assess critically a pressure measurement system marketed for evaluating saddle fit. Validity was tested by calculating the correlation coefficient between total measured pressure and the weight of 28 different riders. Reliability and discriminative power with respect to different saddle fitting methods were evaluated in a highly standardised, paired measurement set-up in which saddle-fit was quantified by air-pressure values inside the panels of the saddle. Total pressures under the saddle correlated well with riders’ weight. A large increase in over-day sensor variation was found. Within trial intra-class correlation coefficients (ICCs) were excellent, but the between trial ICCs varied from poor to excellent and the variation in total pressure was high. In saddles in which the fit was adjusted to individual asymmetries of the horse, the pressure measurement device was able to detect correctly air-pressure differences between the two panels in the back area of the saddle, but not in the front area. The device yielded valid results, but was only reliable in highly standardised conditions. The results question the indiscriminate use of current saddle pressure measurement devices for the quantitative assessment of saddle-fit under practical conditions and suggest that further technical improvement may be necessary. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1090-0233 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
5819 |
|
Permanent link to this record |