Records |
Author |
Kingston, J.K.; Soppet, G.M.; Rogers, C.W.; Firth, E.C. |
Title |
Use of a global positioning and heart rate monitoring system to assess training load in a group of thoroughbred racehorses |
Type |
Journal Article |
Year |
2006 |
Publication |
Equine Veterinary Journal. Supplement |
Abbreviated Journal |
Equine Vet J Suppl |
Volume |
|
Issue |
36 |
Pages |
106-109 |
Keywords |
Analysis of Variance; Animals; Female; *Geographic Information Systems; Heart Rate/*physiology; Horses/*physiology; Male; Monitoring, Physiologic/veterinary; Physical Conditioning, Animal/*physiology; Satellite Communications; Telemetry/methods/*veterinary |
Abstract |
REASONS FOR PERFORMING STUDY: Training is an important variable for determining athletic success. Nonetheless, there has been minimal scientific evaluation of racehorse training programmes. Training of racehorses focuses on running the horses at certain speeds using a combination of a stopwatch and rider's 'feel' for a horse's work intensity. Consequently, actual work intensity for individual horses is not clearly defined. OBJECTIVES: To 1) utilise a combined global positioning system (GPS) and heart rate monitor system to quantify training intensity and physiological responses of a group of racehorses undergoing training and racing; and 2) compare the workload measured by the GPS to that timed and recorded daily by a racehorse trainer. METHODS: Nineteen racehorses age 3 years were followed through a traditional training and racing programme over a 4 month period. Daily GPS and heart rate data together with the trainer's timing and distance data were collected while the horses were trained. Data were analysed using an ANOVA for repeated measures. RESULTS: The combined GPS/heart rate monitoring system detected different heart rate responses in individual horses subjected to the same training workouts. The average speeds detected with the GPS system were in agreement with average speeds timed by the trainer. However, peak speeds reached during training were significantly greater (P<0.05) than those estimated with stopwatch timing. The horses average training speeds increased significantly over the duration of the training period. CONCLUSIONS AND POTENTIAL RELEVANCE: The results from this study show that a GPS/heart rate monitor system provides a reliable measure of daily workload in horses during training. This technology provides a detailed picture of horses' training sessions and has the potential to provide a greater insight into the types of training that may predispose horses to injury. |
Address |
Institute of Veterinary, Animal and Biomedical Sciences, Massey University, Palmerston North, New Zealand |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17402402 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4014 |
Permanent link to this record |
|
|
|
Author |
Bell, R.J.W.; Kingston, J.K.; Mogg, T.D.; Perkins, N.R. |
Title |
The prevalence of gastric ulceration in racehorses in New Zealand |
Type |
Journal Article |
Year |
2007 |
Publication |
New Zealand Veterinary Journal |
Abbreviated Journal |
N Z Vet J |
Volume |
55 |
Issue |
1 |
Pages |
13-18 |
Keywords |
Age Factors; *Animal Feed; Animal Husbandry/methods; Animals; Female; Horse Diseases/*epidemiology/pathology/prevention & control; Horses; Male; New Zealand/epidemiology; Physical Conditioning, Animal/*adverse effects/physiology; Poaceae; Prevalence; Risk Factors; Severity of Illness Index; Sex Factors; Stomach Ulcer/epidemiology/pathology/prevention & control/*veterinary; Time Factors |
Abstract |
AIM: To establish the prevalence and factors influencing the prevalence and severity of gastric ulceration in racehorses in New Zealand. METHODS: Horses (n=171) in active training for racing by trainers (n=24) located throughout New Zealand were examined using gastroscopy during 2003 and 2004. Images of the examination were recorded and reviewed, and an ordinal grade based on the severity of gastric ulceration present was assigned, using the grading system proposed by the Equine Gastric Ulcer Council (EGUC). Information about the horses such as age, breed, sex, stabling, time at pasture, pasture quality, and presence of clinical signs consistent with equine gastric ulcer syndrome (EGUS) was recorded. RESULTS: Of the 171 horses in the study, 133 (78%) were Thoroughbreds and 38 (22%) were Standardbreds. Evidence of gastric ulceration was present in 151 (88.3%) of these. Prevalence of ulceration was higher at the lesser curvature (LC) and greater curvature (GC) of the stomach than at the saccus caecus (SC; p<0.01), and ulceration was more severe at the LC than at either the GC (p=0.02) or the SC (p<0.001). The prevalence of ulceration did not differ between the two breeds (p=0.51) or between horses of differing ages (p=0.56). Gastric ulceration was evident in 125/141 (89%) horses kept at pasture for at least 4 h/day, in all 13 (100%) horses kept at pasture full time, and in 16/17 (94%) horses stabled full time. Prevalence and severity of ulceration did not differ between horses stabled full time, kept at pasture for part of the day or kept at pasture full time (p=0.33 and 0.13, respectively), and for horses grazed on pasture severity of ulceration did not vary significantly with the quality of the pasture (p=0.12). Neither prevalence (p=0.26) nor severity (p=0.49) of gastric ulceration varied significantly with duration of training. CONCLUSIONS: The prevalence of gastric ulceration in racehorses in New Zealand is similar to that reported elsewhere for horses in active training for racing. Access to pasture for some or all of the day did not appear to be protective. |
Address |
Institute of Veterinary, Animal and Biomedical Sciences, Massey University, Private Bag 11222, Palmerston North, New Zealand. robinjw@gmail.com |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0048-0169 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17339911 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4020 |
Permanent link to this record |
|
|
|
Author |
Stadler, P.; Rewel, A.; Deegen, E. |
Title |
[M-mode echocardiography in dressage horses, class S jumping horses and untrained horses] |
Type |
Journal Article |
Year |
1993 |
Publication |
Zentralblatt fur Veterinarmedizin. Reihe A |
Abbreviated Journal |
Zentralbl Veterinarmed A |
Volume |
40 |
Issue |
4 |
Pages |
292-306 |
Keywords |
Animals; Echocardiography/*veterinary; Female; Heart Septum/ultrasonography; Heart Ventricles/ultrasonography; Horses/*anatomy & histology; Male; *Physical Conditioning, Animal; Reference Values |
Abstract |
Heart structures of 45 warmblooded horses were measured by M-mode-echocardiography. The current training level of 15 dressage horses (group I) and 15 show-jumping horses (group II) was category “S”. In the third group were 15 untrained horses. Four standardized transducer positions were determined for the m-mode echobeam, calibrated according to the two-dimensional real time technique. End systolic and end diastolic diameters of left ventricle, right ventricle, aortic root, interventricular septum and left ventricular wall, as well as motion pattern of heart wall, mitral valve and aortic valve of all horses were measured. The dressage horses showed a significant thickening of interventricular septum and left-ventricular wall compared with the show-jumping horses and the untrained horses. The end diastolic left ventricle diameter of the show-jumping horses was significantly larger than in the other groups. Compared to the untrained horses the show-jumping horses showed a significantly larger end systolic left ventricular wall diameter measured at the level of papillary muscle. It can be concluded, that an increase in heart mass in category “S” sport horses is attributed to their level of training. |
Address |
Klinik fur Pferde der Tierarztlichen Hochschule Hannover |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
German |
Summary Language |
|
Original Title |
Die M-mode-Echokardiographie bei S-Dressur-, S-Springpferden und bei untrainierten Pferden |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0514-7158 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:8342361 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
3749 |
Permanent link to this record |
|
|
|
Author |
Cottin, F.; Barrey, E.; Lopes, P.; Billat, V. |
Title |
Effect of repeated exercise and recovery on heart rate variability in elite trotting horses during high intensity interval training |
Type |
Journal Article |
Year |
2006 |
Publication |
Equine Veterinary Journal. Supplement |
Abbreviated Journal |
Equine Vet J Suppl |
Volume |
|
Issue |
36 |
Pages |
204-209 |
Keywords |
Animals; Electrocardiography/veterinary; Fatigue/diagnosis/*veterinary; Fourier Analysis; Heart Rate/*physiology; Horses/*physiology; Physical Conditioning, Animal/*methods/*physiology; Respiration; Time Factors |
Abstract |
REASONS FOR PERFORMING STUDY: Interval training is a commonly used training method for trotting horses. In addition, trainers are provided with efficient and inexpensive heart rate monitor devices for the management of training. HYPOTHESIS: Since the high frequency (HF) frequency peak (fHF) of heart rate variability (HRV) corresponds to the breathing frequency in combination with stride frequency during trotting, it is hypothesised that modifications of breathing and stride frequencies induced by repeated exercise could be detected from fHF. METHODS: RR interval time series of 7 trotting horses were recorded during an interval training session. Interval training was made up of 5 successive 800 m high-velocity trotting runs (H1, H2...H5) separated by 1 min recovery bouts at low speed (R1, R2...R5). Fast Fourier transform (FFT) and Poincare plot analysis techniques were applied to RR series. RESULTS: Repeated exercise had significant effects on HRV components during interval training. Despite constant trotting velocities during high-speed and recovery, repetition induced a decrease in mean RR interval (H1: 295 +/- 19 vs. H5: 283 +/- 15 msec, P<0.05) and in the root mean square of successive differences in RR series (RMSSD; H1: 6.31 +/- 1.28 vs. H5: 5.31 +/- 1.31 msec, P<0.05). Furthermore, high-speed and recovery repetitions induced an increase in fHF (H1: 1.37 +/- 0.35 vs. H5: 1.62 +/- 0.40 Hz and R1: 0.22 +/- 0.02 vs. R4: 0.64 +/- 0.38 Hz, P<0.05). Hence, recovery induced a decrease in the s.d. of the successive RR series (SDRR; R3: 10.5 +/- 3.96 vs. R5: 6.17 +/- 2.65 msecs, P>0.05) and in the long term index of Poincare plot (SD2; R1: 43.29 +/- 28.90 vs. R5: 18.19 +/- 9.35 msecs, P<0.05). CONCLUSIONS: The observed increase in fHF during the interval training could be induced by alterations of the coupling between breathing and stride frequency linked to the emergence of fatigue. The decrease in SD2 and SDRR during successive recovery bouts could be linked with a deterioration of the recovery pattern. POTENTIAL RELEVANCE: HRV can provide breathing frequency data of Standardbreds during training without any respiratory device. Furthermore, HRV could provide useful makers of the emergence of fatigue states during training. |
Address |
Laboratory of Exercise Physiology (LEPHE), University of Evry, E.A. 3872, Genopole, Boulevard F Mitterrand, F-91025 Evry cedex, France |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17402419 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4009 |
Permanent link to this record |
|
|
|
Author |
Rutherford, D.J.; Bladon, B.; Rogers, C.W. |
Title |
Outcome of lag-screw treatment of incomplete fractures of the frontal plane of the radial facet of the third carpal bone in horses |
Type |
Journal Article |
Year |
2007 |
Publication |
New Zealand Veterinary Journal |
Abbreviated Journal |
N Z Vet J |
Volume |
55 |
Issue |
2 |
Pages |
94-99 |
Keywords |
Animals; Bone Screws/*veterinary; Carpus, Animal/radiography/*surgery; Case-Control Studies; Female; Fracture Healing; Horses/*injuries/surgery; Male; Physical Conditioning, Animal; Records/veterinary; Retrospective Studies; Treatment Outcome |
Abstract |
AIM: To describe outcomes for horses diagnosed with incomplete, non-displaced fractures of the frontal plane of the radial facet (INFR) of the third carpal bone (C3) treated by placement of a lag screw across the fracture under arthroscopic guidance. METHODS: Horses (n=13) diagnosed with INFR and treated between December 1999 and January 2005 using a lag screw placed over the fracture were studied. For each case, five horses matched for sire, age and sex which were not known to have INFR were sought for comparison. Racing performance data were collected from a commercial online database. The racing performance of cases pre- and post-operatively, and of cases and matched horses in the post-operative period was compared. RESULTS: Sixteen INFR were found in the 13 horses. Radiographic evidence of healed fracture lines 2-4 months after surgery was seen in 11/16 (69%) fractures; 11/13 (85%) cases raced again after a median recovery period of 292 (range 149-681) days. Treatment was considered successful in 9/13 (69%) cases, which were still in training or had been retired for reasons other than lameness localised to the middle carpal joint at the end of the study period. Just 6/13 (46%) cases had raced prior to injury. The racing ability pre- and post-operatively of five cases was compared, three (60%) of which performed better post-operatively than they had before. There was no significant difference in racing longevity or ability post-operatively between patients and matched (control) horses. CONCLUSIONS: Post-operatively, there was little difference in the racing performance between horses diagnosed with INFR which had a lag screw placed across the fracture line and horses matched for sire, age and sex which were not known to have INFR. CLINICAL RELEVANCE: Horses which were diagnosed with INFR of C3 and had a lag screw placed across the fracture had a good prognosis for future racing performance. |
Address |
Massey Equine, Institute of Veterinary, Animal and Biomedical Sciences, Massey University, Private Bag 11222, Palmerston North, New Zealand. d.j.rutherford@massey.ac.nz |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0048-0169 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17410217 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4001 |
Permanent link to this record |
|
|
|
Author |
Leleu, C.; Cotrel, C. |
Title |
Body composition in young standardbreds in training: relationships to body condition score, physiological and locomotor variables during exercise |
Type |
Journal Article |
Year |
2006 |
Publication |
Equine Veterinary Journal. Supplement |
Abbreviated Journal |
Equine Vet J Suppl |
Volume |
|
Issue |
36 |
Pages |
98-101 |
Keywords |
Adipose Tissue/metabolism; Animals; Body Composition/*physiology; Body Constitution/*physiology; Body Weight/physiology; Exercise Test/veterinary; Female; Gait/physiology; Heart Rate/*physiology; Horses/*physiology; Lactates/blood; Male; Muscle, Skeletal/metabolism; Physical Conditioning, Animal/*physiology |
Abstract |
REASONS FOR PERFORMING STUDY: Body composition is an essential factor in athletic performance of human sprinters and long distance runners. However, in horses, many questions remain concerning relationships between body composition and performance in the different equine activities. OBJECTIVES: To determine relationships between body composition, body score, physiological and locomotor variables in a population of young Standardbreds in training. METHODS: Twenty-four 2-year-old Standardbreds were studied, body condition on a scale 0-5 and bodyweight recorded, and height at withers measured. Percentage of fat (%F), fat mass (FM) and fat free mass (FFM) were estimated echographically. During a standardised exercise test on the track, velocity, heart rate, respiratory frequency and blood lactate concentrations were measured. V4 and V200 (velocity for a blood lactate concentration of 4 mmol/l and velocity of 200 beats/min) calculated. Basic gait variables were measured at 3 different speeds with an accelerometric device. RESULTS: Body composition variables: %F and FM were significantly related to body condition score and physiological variables. Body score was highly correlated to %F (r = 0.64) and FM (r = 0.71). V4 was negatively correlated to %F (r = -0.59) and FM (r = -0.60), P<0.05. V200 was also negatively related to %F and FM, (r = -0.39 and r = -0.37, respectively, P<0.1). No relationships were found between body composition and gait characteristics. CONCLUSIONS: Body composition was closely related to indirect measurements of aerobic capacity, which is a major factor of athletic performance in middle distance running horses. POTENTIAL RELEVANCE: As in human athletes, trainers should take special note to evaluate optimal bodyweight and body composition of race horses to optimise performance. |
Address |
Pegase Mayenne, Departement de Medecine du Sport, Centre Hospitalier, 53 015 Laval, France |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17402400 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4015 |
Permanent link to this record |
|
|
|
Author |
Gerber, V.; Robinson, N.E.; Luethi, S.; Marti, E.; Wampfler, B.; Straub, R. |
Title |
Airway inflammation and mucus in two age groups of asymptomatic well-performing sport horses |
Type |
Journal Article |
Year |
2003 |
Publication |
Equine Veterinary Journal |
Abbreviated Journal |
Equine Vet J |
Volume |
35 |
Issue |
5 |
Pages |
491-495 |
Keywords |
Age Factors; Animals; Bronchoalveolar Lavage Fluid/*cytology; Female; Flow Cytometry/veterinary; Horse Diseases/*physiopathology; Horses; Housing, Animal; Inflammation/veterinary; Leukocyte Count/veterinary; Male; Mucus/*secretion; Physical Conditioning, Animal; Respiratory Function Tests/veterinary; Respiratory Tract Diseases/physiopathology/*veterinary; Sports |
Abstract |
REASONS FOR PERFORMING STUDY: Horses housed in conventional stable environments are exposed to high dust loads. Long-term exposure to inhaled dust may lead to subclinical airway disease. HYPOTHESES: Airway inflammation and mucus accumulation are 1) common in asymptomatic well-performing sport horses, 2) increased in older compared to younger individuals and 3) correlated. METHODS: Mucus quantity and quality (endoscopic scoring) and BALF differential cytology were assessed in 13 younger horses (mean age 5 years) and 13 older horses (mean age 15 years), which had no historical or clinical evidence of lower airway disease, were performing well and were housed permanently in a conventional stable environment. RESULTS: 1) Airway inflammation and/or mucus accumulation were very common. All sport horses showed evidence of subclinical inflammatory airway disease (IAD). 2) Older horses, having been exposed for 10 more years to a conventional stable environment, did not show increased subclinical airway inflammation or mucus accumulation. The only differences between the age groups were increased BALF total and lymphocyte cell counts in the younger horses. 3) Mucus quantity and quality scores were not significantly correlated with each other or with BALF neutrophil percentages and absolute numbers. CONCLUSIONS: Although clinically healthy and performing well, all of the examined horses housed in a conventional stable environment showed evidence of IAD. The degree of IAD was not increased in older horses that had not developed clinical signs. POTENTIAL RELEVANCE: The effect of subclinical degrees of IAD on performance in dressage and show jumping should be investigated further to better understand the clinical significance of IAD in sport horses. |
Address |
Pulmonary Laboratory, Department of Large Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, USA |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0425-1644 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:12875328 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
3721 |
Permanent link to this record |
|
|
|
Author |
Schaer, B.L.D.; Ryan, C.T.; Boston, R.C.; Nunamaker, D.M. |
Title |
The horse-racetrack interface: a preliminary study on the effect of shoeing on impact trauma using a novel wireless data acquisition system |
Type |
Journal Article |
Year |
2006 |
Publication |
Equine Veterinary Journal |
Abbreviated Journal |
Equine Vet J |
Volume |
38 |
Issue |
7 |
Pages |
664-670 |
Keywords |
Animals; Equipment and Supplies/veterinary; Forelimb/injuries/physiology; Hindlimb/injuries/physiology; Hoof and Claw/*physiology; Horses/*injuries/*physiology; Locomotion/physiology; Muscle, Skeletal/injuries/*physiology; *Musculoskeletal Physiology; Musculoskeletal System/*injuries; Physical Conditioning, Animal/*physiology; Risk Factors; Running/physiology; Shoes |
Abstract |
REASONS FOR PERFORMING STUDY: There is a need to determine accelerations acting on the equine hoof under field conditions in order to better assess the risks for orthopaedic health associated with shoeing practices and/or surface conditions. OBJECTIVES: To measure the acceleration profiles generated in Thoroughbred racehorses exercising at high speeds over dirt racetracks and specifically to evaluate the effect of a toe grab shoe compared to a flat racing plate, using a newly developed wireless data acquisition system (WDAS). METHODS: Four Thoroughbred racehorses in training and racing were used. Based on previous trials, each horse served as its own control for speed trials, with shoe type as variable. Horses were evaluated at speeds ranging from 12.0-17.3 m/sec. Impact accelerations, acceleration on break over and take-off, and temporal stride parameters were calculated. Impact injury scores were also determined, using peak accelerations and the time over which they occurred. RESULTS: Recorded accelerations for the resultant vector (all horses all speeds) calculated from triaxial accelerometers ranged 96.3-251.1 g, depending on the phase of the impact event. An association was observed between shoe type and change in acceleration in individual horses, with 2 horses having increased g on initial impact with toe grab shoes in place. In the final impact phase, one horse had an increase of 110 g while wearing toe grab shoes. Increased accelerations were also observed on break over in 2 horses while wearing toe grab shoes. CONCLUSIONS: Shoe type may change impact accelerations significantly in an individual horse and could represent increased risk for injury. Further work is needed to determine if trends exist across a population. POTENTIAL RELEVANCE: The WDAS could be used for performance evaluation in individual horses to evaluate any component of the horse-performance surface interface, with the goal of minimising risk and optimising performance. |
Address |
Richard S. Reynolds Jr. Comparative Orthopedic Research Laboratory, New Bolton Center, University of Pennsylvania School of Veterinary Medicine, Kennett Square, Pennsylvania 19348, USA |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0425-1644 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17228583 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4024 |
Permanent link to this record |
|
|
|
Author |
Ryan, C.T.; Schaer, B.L.D.; Nunamaker, D.M. |
Title |
A novel wireless data acquisition system for the measurement of hoof accelerations in the exercising horse |
Type |
Journal Article |
Year |
2006 |
Publication |
Equine Veterinary Journal |
Abbreviated Journal |
Equine Vet J |
Volume |
38 |
Issue |
7 |
Pages |
671-674 |
Keywords |
*Acceleration; Animals; Biomechanics; Equipment and Supplies/*veterinary; Hoof and Claw/*physiology; Horses/*physiology; Kinetics; Musculoskeletal Physiology; Physical Conditioning, Animal/*physiology; Running/physiology |
Abstract |
REASONS FOR PERFORMING STUDY: A device is needed to safely and wirelessly evaluate accelerations experienced by the horse hoof under a variety of surface conditions with the horse exercising at training or racing speeds. OBJECTIVES: To develop a miniaturised wireless data acquisition system (WDAS) which reliably records hoof accelerations and the times over which they occur in a minimally invasive manner in the exercising Thoroughbred. METHODS: The following criteria were set for device development: production of a lightweight and minimally invasive system, which provides an adequate acceleration range, appropriate frequency response to capture high speed events, and compatibility with a low power wireless telemetry system. Following device development, the WDAS was calibrated, and tested in 6 Thoroughbred horses over a variety of surfaces. RESULTS: Collection of acceleration in seven trials using 6 horses over a variety of surfaces resulted in repeatable acceleration data with respect to the overall characteristic shape of the impact profile. Impact accelerations varied with surface, ranging 34.8-191.7 g. Accelerations on take off were in a similar range, although higher in some trials. Peak impact accelerations tended to larger over the grass paddock surface, than either the indoor arena or the dirt track. During dirt track trials, accelerations on take-off were often comparably larger than those observed on impact within the same footfall. CONCLUSIONS: This study reports the development of a wireless system that successfully measures hoof acceleration in a minimally invasive manner over a variety of surface and exercise conditions. POTENTIAL RELEVANCE: The WDAS will be used in further studies to evaluate various components of the horse-racetrack interface, in an attempt to identify risk factors for musculoskeletal injury in the Thoroughbred racehorse. |
Address |
Richard S. Reynolds, Jr. Comparative Orthopedic Research Laboratory, Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, Pennsylvania 19348, USA |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0425-1644 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17228584 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4023 |
Permanent link to this record |
|
|
|
Author |
Parsons, K.J.; Wilson, A.M. |
Title |
The use of MP3 recorders to log data from equine hoof mounted accelerometers |
Type |
Journal Article |
Year |
2006 |
Publication |
Equine Veterinary Journal |
Abbreviated Journal |
Equine Vet J |
Volume |
38 |
Issue |
7 |
Pages |
675-680 |
Keywords |
Acceleration; Animals; Equipment and Supplies/standards/*veterinary; Hoof and Claw/*physiology; Horses/*physiology; Locomotion/*physiology; Physical Conditioning, Animal/*physiology; Reproducibility of Results; Running/physiology; Sensitivity and Specificity |
Abstract |
REASONS FOR PERFORMING STUDy: MP3 recorders are readily available, small, lightweight and low cost, providing the potential for logging analogue hoof mounted accelerometer signals for the characterisation of equine locomotion. These, however, require testing in practice. OBJECTIVES: To test whether 1) multiple MP3 recorders can maintain synchronisation, giving the ability to synchronise independent recorders for the logging of multiple limbs simultaneously; and 2) features of a foot mounted accelerometer signal attributable to foot-on and foot-off can be accurately identified from horse foot mounted accelerometers logged directly into an MP3 recorder. METHODS: Three experiments were performed: 1) Maintenance of synchronisation was assessed by counting the number of samples recorded by each of 4 MP3 recorders while mounted on a trotting horse and over 2 consecutive 30 min periods in 8 recorders on a bench. 2) Foot-on and foot-off times obtained from manual transcription of MP3 logged data and directly logged accelerometer signal were compared. 3) MP3/accelerometer acquisition units were used to log accelerometer signals from racehorses during extended training sessions. RESULTS: Mean absolute error of synchronisation between MP3 recorders was 10 samples per million (compared to mean number of samples, range 1-32 samples per million). Error accumulation showed a linear correlation with time. Features attributable to foot on and foot off were equally identifiable from the MP3 recorded signal over a range of equine gaits. CONCLUSIONS: Multiple MP3 recorders can be synchronised and used as a relatively cheap, robust, reliable and accurate logging system when combined with an accelerometer and external battery for the specific application of the measurement of stride timing variables across the range of equine gaits during field locomotion. POTENTIAL RELEVANCE: Footfall timings can be used to identify intervals between the fore and hind contacts, the identification of diagonal advanced placement and to calculate stride timing variables (stance time, protraction time and stride time). These parameters are invaluable for the characterisation and assessment of equine locomotion. |
Address |
Structure and Motion Laboratory, The Royal Veterinary College, North Mymms, Hatfield, Hertfordshire AL9 7TA, UK |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0425-1644 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:17228585 |
Approved |
no |
Call Number |
Equine Behaviour @ team @ |
Serial |
4022 |
Permanent link to this record |