|
Records |
Links |
|
Author |
Schaer, B.L.D.; Ryan, C.T.; Boston, R.C.; Nunamaker, D.M. |
|
|
Title |
The horse-racetrack interface: a preliminary study on the effect of shoeing on impact trauma using a novel wireless data acquisition system |
Type |
Journal Article |
|
Year |
2006 |
Publication |
Equine Veterinary Journal |
Abbreviated Journal |
Equine Vet J |
|
|
Volume |
38 |
Issue |
7 |
Pages |
664-670 |
|
|
Keywords |
Animals; Equipment and Supplies/veterinary; Forelimb/injuries/physiology; Hindlimb/injuries/physiology; Hoof and Claw/*physiology; Horses/*injuries/*physiology; Locomotion/physiology; Muscle, Skeletal/injuries/*physiology; *Musculoskeletal Physiology; Musculoskeletal System/*injuries; Physical Conditioning, Animal/*physiology; Risk Factors; Running/physiology; Shoes |
|
|
Abstract |
REASONS FOR PERFORMING STUDY: There is a need to determine accelerations acting on the equine hoof under field conditions in order to better assess the risks for orthopaedic health associated with shoeing practices and/or surface conditions. OBJECTIVES: To measure the acceleration profiles generated in Thoroughbred racehorses exercising at high speeds over dirt racetracks and specifically to evaluate the effect of a toe grab shoe compared to a flat racing plate, using a newly developed wireless data acquisition system (WDAS). METHODS: Four Thoroughbred racehorses in training and racing were used. Based on previous trials, each horse served as its own control for speed trials, with shoe type as variable. Horses were evaluated at speeds ranging from 12.0-17.3 m/sec. Impact accelerations, acceleration on break over and take-off, and temporal stride parameters were calculated. Impact injury scores were also determined, using peak accelerations and the time over which they occurred. RESULTS: Recorded accelerations for the resultant vector (all horses all speeds) calculated from triaxial accelerometers ranged 96.3-251.1 g, depending on the phase of the impact event. An association was observed between shoe type and change in acceleration in individual horses, with 2 horses having increased g on initial impact with toe grab shoes in place. In the final impact phase, one horse had an increase of 110 g while wearing toe grab shoes. Increased accelerations were also observed on break over in 2 horses while wearing toe grab shoes. CONCLUSIONS: Shoe type may change impact accelerations significantly in an individual horse and could represent increased risk for injury. Further work is needed to determine if trends exist across a population. POTENTIAL RELEVANCE: The WDAS could be used for performance evaluation in individual horses to evaluate any component of the horse-performance surface interface, with the goal of minimising risk and optimising performance. |
|
|
Address ![sorted by Address field, ascending order (up)](img/sort_asc.gif) |
Richard S. Reynolds Jr. Comparative Orthopedic Research Laboratory, New Bolton Center, University of Pennsylvania School of Veterinary Medicine, Kennett Square, Pennsylvania 19348, USA |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0425-1644 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:17228583 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
4024 |
|
Permanent link to this record |
|
|
|
|
Author |
Ryan, C.T.; Schaer, B.L.D.; Nunamaker, D.M. |
|
|
Title |
A novel wireless data acquisition system for the measurement of hoof accelerations in the exercising horse |
Type |
Journal Article |
|
Year |
2006 |
Publication |
Equine Veterinary Journal |
Abbreviated Journal |
Equine Vet J |
|
|
Volume |
38 |
Issue |
7 |
Pages |
671-674 |
|
|
Keywords |
*Acceleration; Animals; Biomechanics; Equipment and Supplies/*veterinary; Hoof and Claw/*physiology; Horses/*physiology; Kinetics; Musculoskeletal Physiology; Physical Conditioning, Animal/*physiology; Running/physiology |
|
|
Abstract |
REASONS FOR PERFORMING STUDY: A device is needed to safely and wirelessly evaluate accelerations experienced by the horse hoof under a variety of surface conditions with the horse exercising at training or racing speeds. OBJECTIVES: To develop a miniaturised wireless data acquisition system (WDAS) which reliably records hoof accelerations and the times over which they occur in a minimally invasive manner in the exercising Thoroughbred. METHODS: The following criteria were set for device development: production of a lightweight and minimally invasive system, which provides an adequate acceleration range, appropriate frequency response to capture high speed events, and compatibility with a low power wireless telemetry system. Following device development, the WDAS was calibrated, and tested in 6 Thoroughbred horses over a variety of surfaces. RESULTS: Collection of acceleration in seven trials using 6 horses over a variety of surfaces resulted in repeatable acceleration data with respect to the overall characteristic shape of the impact profile. Impact accelerations varied with surface, ranging 34.8-191.7 g. Accelerations on take off were in a similar range, although higher in some trials. Peak impact accelerations tended to larger over the grass paddock surface, than either the indoor arena or the dirt track. During dirt track trials, accelerations on take-off were often comparably larger than those observed on impact within the same footfall. CONCLUSIONS: This study reports the development of a wireless system that successfully measures hoof acceleration in a minimally invasive manner over a variety of surface and exercise conditions. POTENTIAL RELEVANCE: The WDAS will be used in further studies to evaluate various components of the horse-racetrack interface, in an attempt to identify risk factors for musculoskeletal injury in the Thoroughbred racehorse. |
|
|
Address ![sorted by Address field, ascending order (up)](img/sort_asc.gif) |
Richard S. Reynolds, Jr. Comparative Orthopedic Research Laboratory, Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, Pennsylvania 19348, USA |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0425-1644 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:17228584 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
4023 |
|
Permanent link to this record |
|
|
|
|
Author |
Parsons, K.J.; Wilson, A.M. |
|
|
Title |
The use of MP3 recorders to log data from equine hoof mounted accelerometers |
Type |
Journal Article |
|
Year |
2006 |
Publication |
Equine Veterinary Journal |
Abbreviated Journal |
Equine Vet J |
|
|
Volume |
38 |
Issue |
7 |
Pages |
675-680 |
|
|
Keywords |
Acceleration; Animals; Equipment and Supplies/standards/*veterinary; Hoof and Claw/*physiology; Horses/*physiology; Locomotion/*physiology; Physical Conditioning, Animal/*physiology; Reproducibility of Results; Running/physiology; Sensitivity and Specificity |
|
|
Abstract |
REASONS FOR PERFORMING STUDy: MP3 recorders are readily available, small, lightweight and low cost, providing the potential for logging analogue hoof mounted accelerometer signals for the characterisation of equine locomotion. These, however, require testing in practice. OBJECTIVES: To test whether 1) multiple MP3 recorders can maintain synchronisation, giving the ability to synchronise independent recorders for the logging of multiple limbs simultaneously; and 2) features of a foot mounted accelerometer signal attributable to foot-on and foot-off can be accurately identified from horse foot mounted accelerometers logged directly into an MP3 recorder. METHODS: Three experiments were performed: 1) Maintenance of synchronisation was assessed by counting the number of samples recorded by each of 4 MP3 recorders while mounted on a trotting horse and over 2 consecutive 30 min periods in 8 recorders on a bench. 2) Foot-on and foot-off times obtained from manual transcription of MP3 logged data and directly logged accelerometer signal were compared. 3) MP3/accelerometer acquisition units were used to log accelerometer signals from racehorses during extended training sessions. RESULTS: Mean absolute error of synchronisation between MP3 recorders was 10 samples per million (compared to mean number of samples, range 1-32 samples per million). Error accumulation showed a linear correlation with time. Features attributable to foot on and foot off were equally identifiable from the MP3 recorded signal over a range of equine gaits. CONCLUSIONS: Multiple MP3 recorders can be synchronised and used as a relatively cheap, robust, reliable and accurate logging system when combined with an accelerometer and external battery for the specific application of the measurement of stride timing variables across the range of equine gaits during field locomotion. POTENTIAL RELEVANCE: Footfall timings can be used to identify intervals between the fore and hind contacts, the identification of diagonal advanced placement and to calculate stride timing variables (stance time, protraction time and stride time). These parameters are invaluable for the characterisation and assessment of equine locomotion. |
|
|
Address ![sorted by Address field, ascending order (up)](img/sort_asc.gif) |
Structure and Motion Laboratory, The Royal Veterinary College, North Mymms, Hatfield, Hertfordshire AL9 7TA, UK |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0425-1644 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:17228585 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
4022 |
|
Permanent link to this record |
|
|
|
|
Author |
McGuigan, M.P.; Wilson, A.M. |
|
|
Title |
The effect of gait and digital flexor muscle activation on limb compliance in the forelimb of the horse Equus caballus |
Type |
Journal Article |
|
Year |
2003 |
Publication |
The Journal of Experimental Biology |
Abbreviated Journal |
J Exp Biol |
|
|
Volume |
206 |
Issue |
Pt 8 |
Pages |
1325-1336 |
|
|
Keywords |
Animals; Biomechanics; Forelimb/anatomy & histology/*physiology; Gait/*physiology; Horses/anatomy & histology/*physiology; Muscle Contraction/*physiology; Running |
|
|
Abstract |
A horse's legs are compressed during the stance phase, storing and then returning elastic strain energy in spring-like muscle-tendon units. The arrangement of the muscle-tendon units around the lever-like joints means that as the leg shortens the muscle-tendon units are stretched. The forelimb anatomy means that the leg can be conceptually divided into two springs: the proximal spring, from the scapula to the elbow, and the distal spring, from the elbow to the foot. In this paper we report the results of a series of experiments testing the hypothesis that there is minimal scope for muscle contraction in either spring to adjust limb compliance. Firstly, we demonstrate that the distal, passive leg spring changes length by 127 mm (range 106-128 mm) at gallop and the proximal spring by 12 mm (9-15 mm). Secondly, we demonstrate that there is a linear relationship between limb force and metacarpo-phalangeal (MCP) joint angle that is minimally influenced by digital flexor muscle activation in vitro or as a function of gait in vivo. Finally, we determined the relationship between MCP joint angle and vertical ground-reaction force at trot and then predicted the forelimb peak vertical ground-reaction force during a 12 m s(-1) gallop on a treadmill. These were 12.79 N kg(-1) body mass (BM) (range 12.07-13.73 N kg(-1) BM) for the lead forelimb and 15.23 N kg(-1) BM (13.51-17.10 N kg(-1) BM) for the non-lead forelimb. |
|
|
Address ![sorted by Address field, ascending order (up)](img/sort_asc.gif) |
Structure and Motion Laboratory, Veterinary Basic Sciences, The Royal Veterinary College, Hawkshead Lane, North Mymms, Hatfield, Hertfordshire AL9 7TA, UK. m.p.mcguigan@leeds.ac.uk |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0022-0949 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:12624168 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
3655 |
|
Permanent link to this record |
|
|
|
|
Author |
Clayton, H.M. |
|
|
Title |
Classification of collected trot, passage and piaffe based on temporal variables |
Type |
Journal Article |
|
Year |
1997 |
Publication |
Equine Veterinary Journal. Supplement |
Abbreviated Journal |
Equine Vet J Suppl |
|
|
Volume |
|
Issue |
23 |
Pages |
54-57 |
|
|
Keywords |
Analysis of Variance; Animals; Discriminant Analysis; Gait/*physiology; Hindlimb/physiology; Horses/*physiology; Locomotion/*physiology; Male; Running/physiology; Time Factors; Videotape Recording; Walking/physiology |
|
|
Abstract |
The objective was to determine whether collected trot, passage and piaffe could be distinguished as separate gaits on the basis of temporal variables. Sagittal plane, 60 Hz videotapes of 10 finalists in the dressage competitions at the 1992 Olympic Games were analysed to measure the temporal variables in absolute terms and as percentages of stride duration. Classification was based on analysis of variance, a graphical method and discriminant analysis. Stride duration was sufficient to distinguish collected trot from passage and piaffe in all horses. The analysis of variance showed that the mean values of most variables differed significantly between passage and piaffe. When hindlimb stance percentage was plotted against diagonal advanced placement percentage, some overlap was found between all 3 movements indicating that individual horses could not be classified reliably in this manner. Using hindlimb stance percentage and diagonal advanced placement percentage as input in a discriminant analysis, 80% of the cases were classified correctly, but at least one horse was misclassified in each movement. When the absolute, rather than percentage, values of the 2 variables were used as input in the discriminant analysis, 90% of the cases were correctly classified and the only misclassifications were between passage and piaffe. However, the 2 horses in which piaffe was misclassified as passage were the gold and silver medallists. In general, higher placed horses tended toward longer diagonal advanced placements, especially in collected trot and passage, and shorter hindlimb stance percentages in passage and piaffe. |
|
|
Address ![sorted by Address field, ascending order (up)](img/sort_asc.gif) |
Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, Canada |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
PMID:9354290 |
Approved |
no |
|
|
Call Number |
Equine Behaviour @ team @ |
Serial |
3738 |
|
Permanent link to this record |